How to break the softened water equipment in winter when it can't operate normally?
Water softening equipment is more likely to have some operational problems in winter, which will cause it to not work properly. Therefore, we can only effectively solve the problem if we understand the reasons for the abnormal startup of the reverse osmosis water purification equipment. Today, Sihai will discuss this issue with you:
After years of engineering experience summarizing, it is found that there are several reasons for the abnormal startup of reverse osmosis water purification treatment equipment:
1. The pressure switch is not set correctly:
The pressure switch has an irreplaceable role in the normal operation of the system, ensuring the water supply pressure of the reverse osmosis pure water equipment host and ensuring the normal operation of the related pumps. However, it is common that the host does not start due to incorrect settings.
2, the level controller is damaged or not put:
The liquid level controller is an important control element in the reverse osmosis pure water equipment. Once the reverse osmosis pure water equipment does not start, we must first check whether the liquid level controllers of the following raw water tanks and pure water tanks are malfunctioning.
3, AC contactor failure:
AC contactor failure There are many situations where the main engine water pump does not start due to the damage of the contactor. For example, the AC contactor of the original water pump fails and cannot be automatically closed. Then the rear system must not work. The solution is simple. Replace it. Can be fully resolved.
4. The water pump cannot be started or is damaged:
Directly press the AC contactor in the electric control box and pull it in manually. If the water pump can rotate, the fault of the water pump can be eliminated.
In addition, some areas in the north in winter are very cold and easy to freeze. I hope to do a good job of anti-freezing work for reverse osmosis water purification equipment!